SPE Method for Carbendazim Determination in Orange Juice Using SiliaPrepX™ SCX
SiliCycle has developed the SiliaPrepX™ SCX, a strong cation exchanger polymer sorbent, for specific solid phase extraction of basic compounds (pKa 2 - 10). This polymeric phase is also highly stable in organic solvents.
The performance of the SiliaPrepX SCX polymeric SPE cartridges for the solid phase extraction of carbendazim in orange juice is presented following the link below. The comparison with competitive products at 2 levels of concentration and method accuracy are also evaluated.
-
SiliaChrom® Analytical Guard Cartridge dt C18
The SiliaChrom Guard Cartridges increase the shelf life of the SiliaChrom HPLC Columns by retaining impurities before the analytical columns.