Follow SiliCycle on Facebook Follow SiliCycle on Twitter Follow SiliCycle on LinkedIn Watch our videos on Youtube

SiliaChrom Plus HPLC Columns Portfolio

> back to SiliaChrom Plus HPLC

SiliCycle offers a wide range of chromatographic selectivities to HPLC end-users. Our R&D works to continually enhance our portfolio to suit customer’s requirements and offer unique and powerful new products. Whether you need stability with 100 % aqueous or organic mobile phases or low bleed material for LC/MS applications: we have the solution for you.

Reversed-phases Normal Phases Ion Exchange Phases

 

HPLC Columns Portfolio

SiliaChrom Plus SiliaChrom dt
For your everyday separations100 % aqueous compatible
  • C18 & C18-300 (USP L1)
  • C8 & C8-300 (USP L7)
  • C4 & C4-300 (USP L26)
  • PFP (USP L43)
  • Phenyl (USP L11)
  • Cyano (USP L10)
  • Amine (USP L8)
  • Diol (USP L20)
  • Silica & Silica-300 (USP L3)
  • SAX (USP L14)
  • SCX (USP L9)
C18 (USP L1)
Main Characteristics
  • Wide range of selectivities
  • Ultra pure metal-free silica (99.9999 % purity)
  • High column performance and resolution
  • Enhanced batch-to-batch reproducibility
  • Extended column lifetime
  • Reduced silanol activity, better peak symmetry
  • Extremely low bleeding for LC/MS applications
  • Easy scale-up to preparative formats
  • Ultra pure metal-free silica (99.9999 % purity)
  • High sensitivity for LC/MS
  • Stable from 100 % aqueous to 100 % organic mobile phase
  • Universal: acidic, neutral and basic analysis
  • Enhanced retention of hydrophilic molecules
  • Inertness for acidic and basic analytes

HPLC Column Particle
Size
Pore
Size
Specific Surface Area Carbon
Load
pH
Range
USP Code Temp.
Limit
Pressure
Limit
SiliaChrom Plus C18> 3 μm
> 5 μm
> 10 μm
100 Å370 - 430 m2/g15 %2.0 - 8.0L160°C5,500 psi
SiliaChrom dt C18> 3 μm
> 5 μm
> 10 μm
100 Å410 - 440 m2/g18 %1.5 - 9.0L160°C5,000 psi
SiliaChrom Plus C18-300> 3 μm
> 5 μm
> 10 μm
300 Å80 - 120 m2/g8 %2.0 - 8.0L160°C4,000 psi
SiliaChrom Plus C8> 3 μm
> 5 μm
> 10 μm
100 Å370 - 430 m2/g8 %2.0 - 8.0L760°C5,500 psi
SiliaChrom Plus C8-300> 3 μm
> 5 μm
> 10 μm
300 Å80 - 120 m2/g5 %2.0 - 8.0L760°C4,000 psi
SiliaChrom Plus C4> 3 μm
> 5 μm
> 10 μm
100 Å370 - 430 m2/g6 %2.0 - 8.0L2660°C5,500 psi
SiliaChrom Plus C4-300> 3 μm
> 5 μm
> 10 μm
300 Å80 - 120 m2/g3 %2.0 - 8.0L2660°C4,000 psi
SiliaChrom Plus PFP> 3 μm
> 5 μm
> 10 μm
120 Å320 - 360 m2/g9 %2.0 - 8.0L4360°C5,500 psi
SiliaChrom Plus Phenyl> 3 μm
> 5 μm
> 10 μm
100 Å370 - 430 m2/g7 %2.0 - 8.0L1160°C5,500 psi
SiliaChrom Plus Cyano> 3 μm
> 5 μm
> 10 μm
100 Å370 - 430 m2/g7 %2.0 - 8.0L1060°C5,500 psi
SiliaChrom Plus Amine> 3 μm
> 5 μm
> 10 μm
100 Å370 - 430 m2/g8 %2.0 - 8.0L860°C5,500 psi
SiliaChrom Plus Diol> 3 μm
> 5 μm
> 10 μm
100 Å370 - 430 m2/g7 %2.0 - 8.0L2060°C5,500 psi
SiliaChrom Plus Silica> 3 μm
> 5 μm
> 10 μm
100 Å370 - 430 m2/g-2.0 - 8.0L360°C5,500 psi
SiliaChrom Plus Silica-300> 3 μm
> 5 μm
> 10 μm
300 Å80 - 120 m2/g-2.0 - 8.0L360°C4,000 psi
SiliaChrom Plus SAX> 3 μm
> 5 μm
> 10 μm
Proprietary information2.0 - 8.0L1460°C4,500 psi
SiliaChrom Plus SCX> 3 μm
> 5 μm
2.0 - 8.0L960°C4,500 psi

 

> back to SiliaChrom Plus HPLC

47 Item(s)

Set Descending Direction
per page

List  Grid 

  1. SiliaChrom Plus HPLC Columns, C18, 3 µm, 100 Å (HPL-S03203E-A)

    SiliaChrom Plus HPLC Columns, C18, 3 µm, 100 Å (HPL-S03203E-A)

    SiliaChrom Plus C18 columns will help you with your everyday separations. They are a great start for method development as they present maximum retention for non-polar compounds.
  2. SiliaChrom Plus HPLC Columns, C18, 10 µm, 100 Å (HPL-S03207E-A)

    SiliaChrom Plus HPLC Columns, C18, 10 µm, 100 Å (HPL-S03207E-A)

    SiliaChrom Plus C18 columns will help you with your everyday separations. They are a great start for method development as they present maximum retention for non-polar compounds.
  3. SiliaChrom Plus HPLC Columns, C18, 5 µm, 100 Å (HPL-S03205E-A)

    SiliaChrom Plus HPLC Columns, C18, 5 µm, 100 Å (HPL-S03205E-A)

    SiliaChrom Plus C18 columns will help you with your everyday separations. They are a great start for method development as they present maximum retention for non-polar compounds.
  4. SiliaChrom Plus HPLC Columns, C18, 3 µm, 300 Å (HPL-S03203M)

    SiliaChrom Plus HPLC Columns, C18, 3 µm, 300 Å (HPL-S03203M)

    SiliaChrom Plus C18-300 columns will help you with your larger analytes. The 300 Å porosity allows to analyze and purify polar as well as non-polar proteins greater than 10,000 Dalton.
  5. SiliaChrom Plus HPLC Columns, C18, 10 µm, 300 Å (HPL-S03207M)

    SiliaChrom Plus HPLC Columns, C18, 10 µm, 300 Å (HPL-S03207M)

    SiliaChrom Plus C18-300 columns will help you with your larger analytes. The 300 Å porosity allows to analyze and purify polar as well as non-polar proteins greater than 10,000 Dalton.
  6. SiliaChrom Plus HPLC Columns, C18, 5 µm, 300 Å (HPL-S03205M)

    SiliaChrom Plus HPLC Columns, C18, 5 µm, 300 Å (HPL-S03205M)

    SiliaChrom Plus C18-300 columns will help you with your larger analytes. The 300 Å porosity allows to analyze and purify polar as well as non-polar proteins greater than 10,000 Dalton.
  7. SiliaChrom Plus HPLC Columns, Silica, 3 µm, 100 Å (HPL-S10003E-A)

    SiliaChrom Plus HPLC Columns, Silica, 3 µm, 100 Å (HPL-S10003E-A)

    SiliaChrom Plus Silica is the most polar sorbent of our portfolio, with a slight acidic character. These columns are popular for day-to-day separations of small non-ionic polar organic compounds.
  8. SiliaChrom Plus HPLC Columns, Silica, 5 µm, 100 Å (HPL-S10005E-A)

    SiliaChrom Plus HPLC Columns, Silica, 5 µm, 100 Å (HPL-S10005E-A)

    SiliaChrom Plus Silica is the most polar sorbent of our portfolio, with a slight acidic character. These columns are popular for day-to-day separations of small non-ionic polar organic compounds.
  9. SiliaChrom Plus HPLC Columns, Silica, 10 µm, 100 Å (HPL-S10007E-A)

    SiliaChrom Plus HPLC Columns, Silica, 10 µm, 100 Å (HPL-S10007E-A)

    SiliaChrom Plus Silica is the most polar sorbent of our portfolio, with a slight acidic character. These columns are popular for day-to-day separations of small non-ionic polar organic compounds.
  10. SiliaChrom Plus HPLC Columns, Silica, 3 µm, 300 Å (HPL-S10003M)

    SiliaChrom Plus HPLC Columns, Silica, 3 µm, 300 Å (HPL-S10003M)

    SiliaChrom Plus Silica-300 will help you with your larger polar analytes. The 300 Å porosity allows to analyze and purify polar proteins greater than 10,000 Dalton.
  11. SiliaChrom Plus HPLC Columns, Silica, 5 µm, 300 Å (HPL-S10005M)

    SiliaChrom Plus HPLC Columns, Silica, 5 µm, 300 Å (HPL-S10005M)

    SiliaChrom Plus Silica-300 will help you with your larger polar analytes. The 300 Å porosity allows to analyze and purify polar proteins greater than 10,000 Dalton.
  12. SiliaChrom Plus HPLC Columns, Silica, 10 µm, 300 Å (HPL-S10007M)

    SiliaChrom Plus HPLC Columns, Silica, 10 µm, 300 Å (HPL-S10007M)

    SiliaChrom Plus Silica-300 will help you with your larger polar analytes. The 300 Å porosity allows to analyze and purify polar proteins greater than 10,000 Dalton.
  13. SiliaChrom Plus HPLC Columns, C8, 3 µm, 100 Å (HPL-S30803E-A)

    SiliaChrom Plus HPLC Columns, C8, 3 µm, 100 Å (HPL-S30803E-A)

    SiliaChrom Plus C8 columns will help you with your highly hydrophobic compounds. Less retentive than C18 columns, they are typically used to analyse pesticides, small peptides and heavy drugs, when greater speed is desired.
  14. SiliaChrom Plus HPLC Columns, C8, 5 µm, 100 Å (HPL-S30805E-A)

    SiliaChrom Plus HPLC Columns, C8, 5 µm, 100 Å (HPL-S30805E-A)

    SiliaChrom Plus C8 columns will help you with your highly hydrophobic compounds. Less retentive than C18 columns, they are typically used to analyse pesticides, small peptides and heavy drugs, when greater speed is desired.
  15. SiliaChrom Plus HPLC Columns, C8, 10 µm, 100 Å (HPL-S30807E-A)

    SiliaChrom Plus HPLC Columns, C8, 10 µm, 100 Å (HPL-S30807E-A)

    SiliaChrom Plus C8 columns will help you with your highly hydrophobic compounds. Less retentive than C18 columns, they are typically used to analyse pesticides, small peptides and heavy drugs, when greater speed is desired.
  16. SiliaChrom Plus HPLC Columns, C8, 5 µm, 300 Å (HPL-S30805M)

    SiliaChrom Plus HPLC Columns, C8, 5 µm, 300 Å (HPL-S30805M)

    SiliaChrom Plus C8-300 columns will help you with your large and highly hydrophobic molecules. The 300 Å porosity allows to analyze and purify non-polar proteins greater than 10,000 Dalton.
  17. SiliaChrom Plus HPLC Columns, Phenyl, 3 µm, 100 Å (HPL-S34003E-A)

    SiliaChrom Plus HPLC Columns, Phenyl, 3 µm, 100 Å (HPL-S34003E-A)

    SiliaChrom Plus Phenyl columns represent a good alternative for aromatic non-polar compounds. It is a complementary selectivity to C18 columns: retention is not achieved through hydrophobic interactions only anymore, π-π interactions can also take place.
  18. SiliaChrom Plus HPLC Columns, Phenyl, 5 µm, 100 Å (HPL-S34005E-A)

    SiliaChrom Plus HPLC Columns, Phenyl, 5 µm, 100 Å (HPL-S34005E-A)

    SiliaChrom Plus Phenyl columns represent a good alternative for aromatic non-polar compounds. It is a complementary selectivity to C18 columns: retention is not achieved through hydrophobic interactions only anymore, π-π interactions can also take place.
  19. SiliaChrom Plus HPLC Columns, Phenyl, 10 µm, 100 Å (HPL-S34007E-A)

    SiliaChrom Plus HPLC Columns, Phenyl, 10 µm, 100 Å (HPL-S34007E-A)

    SiliaChrom Plus Phenyl columns represent a good alternative for aromatic non-polar compounds. It is a complementary selectivity to C18 columns: retention is not achieved through hydrophobic interactions only anymore, π-π interactions can also take place.
  20. SiliaChrom Plus HPLC Columns, Diol, 3 µm, 100 Å (HPL-S35003E-A)

    SiliaChrom Plus HPLC Columns, Diol, 3 µm, 100 Å (HPL-S35003E-A)

    SiliaChrom Plus Diol columns are ideal for difficult separations of low to medium polarity samples. They can be used for sugars analysis (carbohydrates, glycosides and oligosaccharides) and vitamins analysis. SiliaChrom Plus Diol columns are also compatible with HILIC mode (Hydrophilic Interaction LIquid Chromatography).
  21. SiliaChrom Plus HPLC Columns, Diol, 5 µm, 100 Å (HPL-S35005E-A)

    SiliaChrom Plus HPLC Columns, Diol, 5 µm, 100 Å (HPL-S35005E-A)

    SiliaChrom Plus Diol columns are ideal for difficult separations of low to medium polarity samples. They can be used for sugars analysis (carbohydrates, glycosides and oligosaccharides) and vitamins analysis. SiliaChrom Plus Diol columns are also compatible with HILIC mode (Hydrophilic Interaction LIquid Chromatography).
  22. SiliaChrom Plus HPLC Columns, Diol, 10 µm, 100 Å (HPL-S35007E-A)

    SiliaChrom Plus HPLC Columns, Diol, 10 µm, 100 Å (HPL-S35007E-A)

    SiliaChrom Plus Diol columns are ideal for difficult separations of low to medium polarity samples. They can be used for sugars analysis (carbohydrates, glycosides and oligosaccharides) and vitamins analysis. SiliaChrom Plus Diol columns are also compatible with HILIC mode (Hydrophilic Interaction LIquid Chromatography).
  23. SiliaChrom Plus HPLC Columns, Cyano, 3 µm, 100 Å (HPL-S38003E-A)

    SiliaChrom Plus HPLC Columns, Cyano, 3 µm, 100 Å (HPL-S38003E-A)

    SiliaChrom Plus Cyano columns can be used both in normal and reversed-phase. Less polar than silica, they will help retain organic compounds with intermediate to extreme polarity. Whether you need to analyse carbohydrates, glycosides, cyclosporine or any other carboxyl / carbonyl / amine containing molecules, SiliaChrom Plus Cyano is a good choice.
  24. SiliaChrom Plus HPLC Columns, Cyano, 5 µm, 100 Å (HPL-S38005E-A)

    SiliaChrom Plus HPLC Columns, Cyano, 5 µm, 100 Å (HPL-S38005E-A)

    SiliaChrom Plus Cyano columns can be used both in normal and reversed-phase. Less polar than silica, they will help retain organic compounds with intermediate to extreme polarity. Whether you need to analyse carbohydrates, glycosides, cyclosporine or any other carboxyl / carbonyl / amine containing molecules, SiliaChrom Plus Cyano is a good choice.
  25. SiliaChrom Plus HPLC Columns, Cyano, 10 µm, 100 Å (HPL-S38007E-A)

    SiliaChrom Plus HPLC Columns, Cyano, 10 µm, 100 Å (HPL-S38007E-A)

    SiliaChrom Plus Cyano columns can be used both in normal and reversed-phase. Less polar than silica, they will help retain organic compounds with intermediate to extreme polarity. Whether you need to analyse carbohydrates, glycosides, cyclosporine or any other carboxyl / carbonyl / amine containing molecules, SiliaChrom Plus Cyano is a good choice.
  26. SiliaChrom Plus HPLC Columns, Amino, 3 µm, 100 Å (HPL-S52003E-A)

    SiliaChrom Plus HPLC Columns, Amine, 3 µm, 100 Å (HPL-S52003E-A)

    SiliaChrom Plus Amine columns are very popular for sugars analysis (carbohydrates, glycosides and oligosaccharides). They represent a good alternative for normal phase separation of compounds with acidic/basic properties. SiliaChrom Plus Amine columns can also be used in Ion Exchange Mode, for retention & release of very strong anions such as sulfonic acids.
  27. SiliaChrom Plus HPLC Columns, Amine, 5 µm, 100 Å (HPL-S52005E-A)

    SiliaChrom Plus HPLC Columns, Amine, 5 µm, 100 Å (HPL-S52005E-A)

    SiliaChrom Plus Amine columns are very popular for sugars analysis (carbohydrates, glycosides and oligosaccharides). They represent a good alternative for normal phase separation of compounds with acidic/basic properties. SiliaChrom Plus Amine columns can also be used in Ion Exchange Mode, for retention & release of very strong anions such as sulfonic acids.
  28. SiliaChrom Plus HPLC Columns, Amine, 10 µm, 100 Å (HPL-S52007E-A)

    SiliaChrom Plus HPLC Columns, Amine, 10 µm, 100 Å (HPL-S52007E-A)

    SiliaChrom Plus Amine columns are very popular for sugars analysis (carbohydrates, glycosides and oligosaccharides). They represent a good alternative for normal phase separation of compounds with acidic/basic properties. SiliaChrom Plus Amine columns can also be used in Ion Exchange Mode, for retention & release of very strong anions such as sulfonic acids.
  29. SiliaChrom Plus HPLC Columns, SAX, 3 µm, 100 Å (HPL-S66503E-A)

    SiliaChrom Plus HPLC Columns, SAX, 3 µm (HPL-S66503E-A)

    SiliaChrom Plus SAX columns (Strong Anion Exchange) are used for retention & release of weak acidic anions, such as carboxylic acids, that may not bind strongly enough to weaker anion exchangers (for example Amine columns).
  30. SiliaChrom Plus HPLC Columns, SAX, 5 µm, 100 Å (HPL-S66505E-A)

    SiliaChrom Plus HPLC Columns, SAX, 5 µm (HPL-S66505E-A)

    SiliaChrom Plus SAX columns (Strong Anion Exchange) are used for retention & release of weak acidic anions, such as carboxylic acids, that may not bind strongly enough to weaker anion exchangers (for example Amine columns).
  31. SiliaChrom Plus HPLC Columns, SAX, 10 µm, 100 Å (HPL-S66507E-A)

    SiliaChrom Plus HPLC Columns, SAX, 10 µm (HPL-S66507E-A)

    SiliaChrom Plus SAX columns (Strong Anion Exchange) are used for retention & release of weak acidic anions, such as carboxylic acids, that may not bind strongly enough to weaker anion exchangers (for example Amine columns).
  32. SiliaChrom Plus HPLC Columns, Pentafluorophenyl (PFP), 3 µm, 120 Å (HPL-S67503G-A)

    SiliaChrom Plus HPLC Columns, Pentafluorophenyl (PFP), 3 µm, 120 Å (HPL-S67503G-A)

    SiliaChrom Plus PFP columns represent a good alternative for aromatic and polar compounds. It is a complementary selectivity to C18 columns. Both could be tested as first attempts in method development when analysing conjugated molecules (isomers) or complex natural products for example.
  33. SiliaChrom Plus HPLC Columns, Pentafluorophenyl (PFP), 5 µm, 120 Å (HPL-S67505G-A)

    SiliaChrom Plus HPLC Columns, Pentafluorophenyl (PFP), 5 µm, 120 Å (HPL-S67505G-A)

    SiliaChrom Plus PFP columns represent a good alternative for aromatic and polar compounds. It is a complementary selectivity to C18 columns. Both could be tested as first attempts in method development when analysing conjugated molecules (isomers) or complex natural products for example.
  34. SiliaChrom Plus HPLC Columns, Pentafluorophenyl (PFP), 10 µm, 120 Å (HPL-S67507G-A)

    SiliaChrom Plus HPLC Columns, Pentafluorophenyl (PFP), 10 µm, 120 Å (HPL-S67507G-A)

    SiliaChrom Plus PFP columns represent a good alternative for aromatic and polar compounds. It is a complementary selectivity to C18 columns. Both could be tested as first attempts in method development when analysing conjugated molecules (isomers) or complex natural products for example.
  35. SiliaChrom Plus HPLC Columns, SCX, 3 µm (HPL-S90003)

    SiliaChrom Plus HPLC Columns, SCX, 3 µm (HPL-S90003)

    SiliaChrom Plus SCX columns (Strong Cation Exchange) provide excellent resolution and peak shape for cationic analytes. The benzene sulfonic acid function allows ionic and π-π interactions to take place. SiliaChrom Plus SCX columns are used for specific analysis of amino acids, anilines, drug salts, inorganic cations and nucleosides.
  36. SiliaChrom Plus HPLC Columns, C4, 5 µm, 100 Å (HPL-S32705E-A)

    SiliaChrom Plus HPLC Columns, C4, 5 µm, 100 Å (HPL-S32705E-A)

    SiliaChrom Plus C4 columns will help you with your most hydrophobic compounds. Less retentive than C18 and C8 columns, they are typically used to analyse highly non-polar pesticides, peptides and drugs, when less retention and greater speed are desired.
  37. SiliaChrom Plus HPLC Columns, SCX, 5 µm (HPL-S90005)

    SiliaChrom Plus HPLC Columns, SCX, 5 µm (HPL-S90005)

    SiliaChrom Plus SCX columns (Strong Cation Exchange) provide excellent resolution and peak shape for cationic analytes. The benzene sulfonic acid function allows ionic and π-π interactions to take place. SiliaChrom Plus SCX columns are used for specific analysis of amino acids, anilines, drug salts, inorganic cations and nucleosides.
  38. SiliaChrom Plus HPLC Columns, C4, 10 µm, 100 Å (HPL-S32707E-A)

    SiliaChrom Plus HPLC Columns, C4, 10 µm, 100 Å (HPL-S32707E-A)

    SiliaChrom Plus C4 columns will help you with your most hydrophobic compounds. Less retentive than C18 and C8 columns, they are typically used to analyse highly non-polar pesticides, peptides and drugs, when less retention and greater speed are desired.
  39. SiliaChrom Plus HPLC Columns, C4, 3 µm, 300 Å (HPL-S32703M)

    SiliaChrom Plus HPLC Columns, C4, 3 µm, 300 Å (HPL-S32703M)

    SiliaChrom Plus C4-300 columns will help you with your large & hydrophobic molecules that stick too much on C18 columns. The 300 Å porosity allows to analyze and purify non-polar proteins greater than 10,000 Dalton.
  40. SiliaChrom Plus HPLC Columns, C4, 5 µm, 300 Å (HPL-S32705M)

    SiliaChrom Plus HPLC Columns, C4, 5 µm, 300 Å (HPL-S32705M)

    SiliaChrom Plus C4-300 columns will help you with your large & hydrophobic molecules that stick too much on C18 columns. The 300 Å porosity allows to analyze and purify non-polar proteins greater than 10,000 Dalton.
  41. SiliaChrom Plus HPLC Columns, C4, 10 µm, 300 Å (HPL-S32707M)

    SiliaChrom Plus HPLC Columns, C4, 10 µm, 300 Å (HPL-S32707M)

    SiliaChrom Plus C4-300 columns will help you with your large & hydrophobic molecules that stick too much on C18 columns. The 300 Å porosity allows to analyze and purify non-polar proteins greater than 10,000 Dalton.
  42. SiliaChrom Plus HPLC Columns, C8, 3 µm, 300 Å (HPL-S30803M)

    SiliaChrom Plus HPLC Columns, C8, 3 µm, 300 Å (HPL-S30803M)

    SiliaChrom Plus C8-300 columns will help you with your large and highly hydrophobic molecules. The 300 Å porosity allows to analyze and purify non-polar proteins greater than 10,000 Dalton.
  43. SiliaChrom Plus HPLC Columns, C8, 10 µm, 300 Å (HPL-S30807M)

    SiliaChrom Plus HPLC Columns, C8, 10 µm, 300 Å (HPL-S30807M)

    SiliaChrom Plus C8-300 columns will help you with your large and highly hydrophobic molecules. The 300 Å porosity allows to analyze and purify non-polar proteins greater than 10,000 Dalton.
  44. SiliaChrom Plus HPLC Columns, C4, 3 µm, 100 Å (HPL-S32703E-A)

    SiliaChrom Plus HPLC Columns, C4, 3 µm, 100 Å (HPL-S32703E-A)

    SiliaChrom Plus C4 columns will help you with your most hydrophobic compounds. Less retentive than C18 and C8 columns, they are typically used to analyse highly non-polar pesticides, peptides and drugs, when less retention and greater speed are desired.
  45. SiliaChrom HPLC Columns, dt C18, 3 µm, 100 Å (H141803E)

    SiliaChrom HPLC Columns, dt C18, 3 µm, 100 Å (H141803E)

    SiliaChrom dt C18 columns will help you with your separations under 100 % aqueous conditions. The phase will not collapse, as most C18 would. Whether you need to analyse hydrophobic or hydrophilic compounds, with buffered mobile phase only, SiliaChrom Plus dt C18 is a safe choice.
  46. SiliaChrom HPLC Columns, dt C18, 5 µm, 100 Å (H141805E)

    SiliaChrom HPLC Columns, dt C18, 5 µm, 100 Å (H141805E)

    SiliaChrom dt C18 columns will help you with your separations under 100 % aqueous conditions. The phase will not collapse, as most C18 would. Whether you need to analyse hydrophobic or hydrophilic compounds, with buffered mobile phase only, SiliaChrom dt C18 is a safe choice.
  47. SiliaChrom HPLC Columns, dt C18, 10 µm, 100 Å (H141807E)

    SiliaChrom HPLC Columns, dt C18, 10 µm, 100 Å (H141807E)

    SiliaChrom dt C18 columns will help you with your separations under 100 % aqueous conditions. The phase will not collapse, as most C18 would. Whether you need to analyse hydrophobic or hydrophilic compounds, with buffered mobile phase only, SiliaChrom dt C18 is a safe choice.

47 Item(s)

Set Descending Direction
per page

List  Grid