Follow SiliCycle on Facebook Follow SiliCycle on Twitter Follow SiliCycle on LinkedIn Watch our videos on Youtube

SiliaChrom Plus HPLC Columns - Reversed Phases

> back to SiliaChrom Plus HPLC Columns

All columns are offered in 3, 5 & 10 µm particle size.

Available phases:

  • C18 (100 Å & 300 Å)
  • dt C18 (100 Å)
  • C8 (100 Å & 300 Å)
  • C4 (100 Å & 300 Å)
  • Cyano (100 Å)
  • Pentafluorophenyl / PFP (120 Å)
  • Phenyl (100 Å)

30 Item(s)

Set Descending Direction
per page

List  Grid 

  1. SiliaChrom Plus HPLC Columns, C18, 3 µm, 100 Å (HPL-S03203E-A)

    SiliaChrom Plus HPLC Columns, C18, 3 µm, 100 Å (HPL-S03203E-A)

    SiliaChrom Plus C18 columns will help you with your everyday separations. They are a great start for method development as they present maximum retention for non-polar compounds.
  2. SiliaChrom Plus HPLC Columns, C18, 10 µm, 100 Å (HPL-S03207E-A)

    SiliaChrom Plus HPLC Columns, C18, 10 µm, 100 Å (HPL-S03207E-A)

    SiliaChrom Plus C18 columns will help you with your everyday separations. They are a great start for method development as they present maximum retention for non-polar compounds.
  3. SiliaChrom Plus HPLC Columns, C18, 5 µm, 100 Å (HPL-S03205E-A)

    SiliaChrom Plus HPLC Columns, C18, 5 µm, 100 Å (HPL-S03205E-A)

    SiliaChrom Plus C18 columns will help you with your everyday separations. They are a great start for method development as they present maximum retention for non-polar compounds.
  4. SiliaChrom Plus HPLC Columns, C18, 3 µm, 300 Å (HPL-S03203M)

    SiliaChrom Plus HPLC Columns, C18, 3 µm, 300 Å (HPL-S03203M)

    SiliaChrom Plus C18-300 columns will help you with your larger analytes. The 300 Å porosity allows to analyze and purify polar as well as non-polar proteins greater than 10,000 Dalton.
  5. SiliaChrom Plus HPLC Columns, C18, 10 µm, 300 Å (HPL-S03207M)

    SiliaChrom Plus HPLC Columns, C18, 10 µm, 300 Å (HPL-S03207M)

    SiliaChrom Plus C18-300 columns will help you with your larger analytes. The 300 Å porosity allows to analyze and purify polar as well as non-polar proteins greater than 10,000 Dalton.
  6. SiliaChrom Plus HPLC Columns, C18, 5 µm, 300 Å (HPL-S03205M)

    SiliaChrom Plus HPLC Columns, C18, 5 µm, 300 Å (HPL-S03205M)

    SiliaChrom Plus C18-300 columns will help you with your larger analytes. The 300 Å porosity allows to analyze and purify polar as well as non-polar proteins greater than 10,000 Dalton.
  7. SiliaChrom Plus HPLC Columns, C8, 3 µm, 100 Å (HPL-S30803E-A)

    SiliaChrom Plus HPLC Columns, C8, 3 µm, 100 Å (HPL-S30803E-A)

    SiliaChrom Plus C8 columns will help you with your highly hydrophobic compounds. Less retentive than C18 columns, they are typically used to analyse pesticides, small peptides and heavy drugs, when greater speed is desired.
  8. SiliaChrom Plus HPLC Columns, C8, 5 µm, 100 Å (HPL-S30805E-A)

    SiliaChrom Plus HPLC Columns, C8, 5 µm, 100 Å (HPL-S30805E-A)

    SiliaChrom Plus C8 columns will help you with your highly hydrophobic compounds. Less retentive than C18 columns, they are typically used to analyse pesticides, small peptides and heavy drugs, when greater speed is desired.
  9. SiliaChrom Plus HPLC Columns, C8, 10 µm, 100 Å (HPL-S30807E-A)

    SiliaChrom Plus HPLC Columns, C8, 10 µm, 100 Å (HPL-S30807E-A)

    SiliaChrom Plus C8 columns will help you with your highly hydrophobic compounds. Less retentive than C18 columns, they are typically used to analyse pesticides, small peptides and heavy drugs, when greater speed is desired.
  10. SiliaChrom Plus HPLC Columns, C8, 5 µm, 300 Å (HPL-S30805M)

    SiliaChrom Plus HPLC Columns, C8, 5 µm, 300 Å (HPL-S30805M)

    SiliaChrom Plus C8-300 columns will help you with your large and highly hydrophobic molecules. The 300 Å porosity allows to analyze and purify non-polar proteins greater than 10,000 Dalton.
  11. SiliaChrom Plus HPLC Columns, Phenyl, 3 µm, 100 Å (HPL-S34003E-A)

    SiliaChrom Plus HPLC Columns, Phenyl, 3 µm, 100 Å (HPL-S34003E-A)

    SiliaChrom Plus Phenyl columns represent a good alternative for aromatic non-polar compounds. It is a complementary selectivity to C18 columns: retention is not achieved through hydrophobic interactions only anymore, π-π interactions can also take place.
  12. SiliaChrom Plus HPLC Columns, Phenyl, 5 µm, 100 Å (HPL-S34005E-A)

    SiliaChrom Plus HPLC Columns, Phenyl, 5 µm, 100 Å (HPL-S34005E-A)

    SiliaChrom Plus Phenyl columns represent a good alternative for aromatic non-polar compounds. It is a complementary selectivity to C18 columns: retention is not achieved through hydrophobic interactions only anymore, π-π interactions can also take place.
  13. SiliaChrom Plus HPLC Columns, Phenyl, 10 µm, 100 Å (HPL-S34007E-A)

    SiliaChrom Plus HPLC Columns, Phenyl, 10 µm, 100 Å (HPL-S34007E-A)

    SiliaChrom Plus Phenyl columns represent a good alternative for aromatic non-polar compounds. It is a complementary selectivity to C18 columns: retention is not achieved through hydrophobic interactions only anymore, π-π interactions can also take place.
  14. SiliaChrom Plus HPLC Columns, Cyano, 3 µm, 100 Å (HPL-S38003E-A)

    SiliaChrom Plus HPLC Columns, Cyano, 3 µm, 100 Å (HPL-S38003E-A)

    SiliaChrom Plus Cyano columns can be used both in normal and reversed-phase. Less polar than silica, they will help retain organic compounds with intermediate to extreme polarity. Whether you need to analyse carbohydrates, glycosides, cyclosporine or any other carboxyl / carbonyl / amine containing molecules, SiliaChrom Plus Cyano is a good choice.
  15. SiliaChrom Plus HPLC Columns, Cyano, 5 µm, 100 Å (HPL-S38005E-A)

    SiliaChrom Plus HPLC Columns, Cyano, 5 µm, 100 Å (HPL-S38005E-A)

    SiliaChrom Plus Cyano columns can be used both in normal and reversed-phase. Less polar than silica, they will help retain organic compounds with intermediate to extreme polarity. Whether you need to analyse carbohydrates, glycosides, cyclosporine or any other carboxyl / carbonyl / amine containing molecules, SiliaChrom Plus Cyano is a good choice.
  16. SiliaChrom Plus HPLC Columns, Cyano, 10 µm, 100 Å (HPL-S38007E-A)

    SiliaChrom Plus HPLC Columns, Cyano, 10 µm, 100 Å (HPL-S38007E-A)

    SiliaChrom Plus Cyano columns can be used both in normal and reversed-phase. Less polar than silica, they will help retain organic compounds with intermediate to extreme polarity. Whether you need to analyse carbohydrates, glycosides, cyclosporine or any other carboxyl / carbonyl / amine containing molecules, SiliaChrom Plus Cyano is a good choice.
  17. SiliaChrom Plus HPLC Columns, Pentafluorophenyl (PFP), 3 µm, 120 Å (HPL-S67503G-A)

    SiliaChrom Plus HPLC Columns, Pentafluorophenyl (PFP), 3 µm, 120 Å (HPL-S67503G-A)

    SiliaChrom Plus PFP columns represent a good alternative for aromatic and polar compounds. It is a complementary selectivity to C18 columns. Both could be tested as first attempts in method development when analysing conjugated molecules (isomers) or complex natural products for example.
  18. SiliaChrom Plus HPLC Columns, Pentafluorophenyl (PFP), 5 µm, 120 Å (HPL-S67505G-A)

    SiliaChrom Plus HPLC Columns, Pentafluorophenyl (PFP), 5 µm, 120 Å (HPL-S67505G-A)

    SiliaChrom Plus PFP columns represent a good alternative for aromatic and polar compounds. It is a complementary selectivity to C18 columns. Both could be tested as first attempts in method development when analysing conjugated molecules (isomers) or complex natural products for example.
  19. SiliaChrom Plus HPLC Columns, Pentafluorophenyl (PFP), 10 µm, 120 Å (HPL-S67507G-A)

    SiliaChrom Plus HPLC Columns, Pentafluorophenyl (PFP), 10 µm, 120 Å (HPL-S67507G-A)

    SiliaChrom Plus PFP columns represent a good alternative for aromatic and polar compounds. It is a complementary selectivity to C18 columns. Both could be tested as first attempts in method development when analysing conjugated molecules (isomers) or complex natural products for example.
  20. SiliaChrom Plus HPLC Columns, C4, 5 µm, 100 Å (HPL-S32705E-A)

    SiliaChrom Plus HPLC Columns, C4, 5 µm, 100 Å (HPL-S32705E-A)

    SiliaChrom Plus C4 columns will help you with your most hydrophobic compounds. Less retentive than C18 and C8 columns, they are typically used to analyse highly non-polar pesticides, peptides and drugs, when less retention and greater speed are desired.
  21. SiliaChrom Plus HPLC Columns, C4, 10 µm, 100 Å (HPL-S32707E-A)

    SiliaChrom Plus HPLC Columns, C4, 10 µm, 100 Å (HPL-S32707E-A)

    SiliaChrom Plus C4 columns will help you with your most hydrophobic compounds. Less retentive than C18 and C8 columns, they are typically used to analyse highly non-polar pesticides, peptides and drugs, when less retention and greater speed are desired.
  22. SiliaChrom Plus HPLC Columns, C4, 3 µm, 300 Å (HPL-S32703M)

    SiliaChrom Plus HPLC Columns, C4, 3 µm, 300 Å (HPL-S32703M)

    SiliaChrom Plus C4-300 columns will help you with your large & hydrophobic molecules that stick too much on C18 columns. The 300 Å porosity allows to analyze and purify non-polar proteins greater than 10,000 Dalton.
  23. SiliaChrom Plus HPLC Columns, C4, 5 µm, 300 Å (HPL-S32705M)

    SiliaChrom Plus HPLC Columns, C4, 5 µm, 300 Å (HPL-S32705M)

    SiliaChrom Plus C4-300 columns will help you with your large & hydrophobic molecules that stick too much on C18 columns. The 300 Å porosity allows to analyze and purify non-polar proteins greater than 10,000 Dalton.
  24. SiliaChrom Plus HPLC Columns, C4, 10 µm, 300 Å (HPL-S32707M)

    SiliaChrom Plus HPLC Columns, C4, 10 µm, 300 Å (HPL-S32707M)

    SiliaChrom Plus C4-300 columns will help you with your large & hydrophobic molecules that stick too much on C18 columns. The 300 Å porosity allows to analyze and purify non-polar proteins greater than 10,000 Dalton.
  25. SiliaChrom Plus HPLC Columns, C8, 3 µm, 300 Å (HPL-S30803M)

    SiliaChrom Plus HPLC Columns, C8, 3 µm, 300 Å (HPL-S30803M)

    SiliaChrom Plus C8-300 columns will help you with your large and highly hydrophobic molecules. The 300 Å porosity allows to analyze and purify non-polar proteins greater than 10,000 Dalton.
  26. SiliaChrom Plus HPLC Columns, C8, 10 µm, 300 Å (HPL-S30807M)

    SiliaChrom Plus HPLC Columns, C8, 10 µm, 300 Å (HPL-S30807M)

    SiliaChrom Plus C8-300 columns will help you with your large and highly hydrophobic molecules. The 300 Å porosity allows to analyze and purify non-polar proteins greater than 10,000 Dalton.
  27. SiliaChrom Plus HPLC Columns, C4, 3 µm, 100 Å (HPL-S32703E-A)

    SiliaChrom Plus HPLC Columns, C4, 3 µm, 100 Å (HPL-S32703E-A)

    SiliaChrom Plus C4 columns will help you with your most hydrophobic compounds. Less retentive than C18 and C8 columns, they are typically used to analyse highly non-polar pesticides, peptides and drugs, when less retention and greater speed are desired.
  28. SiliaChrom HPLC Columns, dt C18, 3 µm, 100 Å (H141803E)

    SiliaChrom HPLC Columns, dt C18, 3 µm, 100 Å (H141803E)

    SiliaChrom dt C18 columns will help you with your separations under 100 % aqueous conditions. The phase will not collapse, as most C18 would. Whether you need to analyse hydrophobic or hydrophilic compounds, with buffered mobile phase only, SiliaChrom Plus dt C18 is a safe choice.
  29. SiliaChrom HPLC Columns, dt C18, 5 µm, 100 Å (H141805E)

    SiliaChrom HPLC Columns, dt C18, 5 µm, 100 Å (H141805E)

    SiliaChrom dt C18 columns will help you with your separations under 100 % aqueous conditions. The phase will not collapse, as most C18 would. Whether you need to analyse hydrophobic or hydrophilic compounds, with buffered mobile phase only, SiliaChrom dt C18 is a safe choice.
  30. SiliaChrom HPLC Columns, dt C18, 10 µm, 100 Å (H141807E)

    SiliaChrom HPLC Columns, dt C18, 10 µm, 100 Å (H141807E)

    SiliaChrom dt C18 columns will help you with your separations under 100 % aqueous conditions. The phase will not collapse, as most C18 would. Whether you need to analyse hydrophobic or hydrophilic compounds, with buffered mobile phase only, SiliaChrom dt C18 is a safe choice.

30 Item(s)

Set Descending Direction
per page

List  Grid