SiliaFlash Irregular Silica Gels Portfolio by Pore Diameter
30 Â 40 Â 60 Â 90 Â 150 Â 300 Â
> back to SiliaFlash Irregular Silica Gels Portfolio
With pore diameters ranging from 30 to 300 Ångströms (Å), SiliCycle offers irregular silica gels that will meet all your requirements!
-
SiliaFlash Irregular Silica Gel, 75 - 150 µm, 30 Å (R10137L)
Particles for Gravity Chromatography: most economical silica for open column chromatography. Suitable for very dirty purification, Easier to handle. Suitable for Organic Molecules (MW < 1,000 Dalton). -
SiliaFlash Irregular Silica Gel F40, 40 - 63 µm, 40 Å (R10130A)
Particles for Flash Chromatography: silica for flash & low to medium-pressure preparative chromatography. Narrow particle size distribution, Easier to pack and more uniform packing, Superior resolution, Suitable for use with complex matrices. Suitable for Organic Molecules (MW < 1,000 Dalton). -
SiliaFlash Irregular Silica Gel, B40, 200 - 500 µm, 40 Å (R10170A)
Particles for other applications, such as silica for plugs. Suitable for Organic Molecules (MW < 1,000 Dalton). -
SiliaFlash Irregular Silica Gel F40, 60 - 200 µm, 40 Å (R10140A)
Particles for Gravity Chromatography: Most economical silica for open column chromatography. Suitable for very dirty purification, Easier to handle. Suitable for Organic Molecules (MW < 1,000 Dalton). -
-
-
-
SiliaFlash Irregular Silica Gel R60, 20 - 45 µm, 60 Å (R10023B)
Particles for difficult separations (similar polarities): high-resolution silica (higher back-pressure) -
SiliaFlash Irregular Silica Gels F60, 40 - 63 µm, 60 Å (R10030B)
Particles for Flash Chromatography: silica for flash & low to medium-pressure preparative chromatography. Narrow particle size distribution, Easier to pack and more uniform packing, Superior resolution, Suitable for use with complex matrices -
SiliaFlash Irregular Silica Gel P60, 40 - 63 µm, 60 Å (R12030B)
Particles for Flash Chromatography: silica for flash & low to medium-pressure preparative chromatography. Narrow particle size distribution, Easier to pack and more uniform packing, Superior resolution, Suitable for use with complex matrices. -
SiliaFlash Irregular Silica Gel G60, 60 - 200 µm, 60 Å (R10040B)
Particles for Gravity Chromatography: Most economical silica for open column chromatography. Suitable for very dirty purification, Easier to handle. -
SiliaFlash Irregular Silica Gel L60, 120 - 200 µm, 60 Å (R10160B)
Particles for Gravity Chromatography: silica for standard open column chromatography. Narrow particle size distribution enables uniform packing, Suitable for mass overload purification. -
SiliaFlash Irregular Silica Gel BE60, 200 - 500 µm, 60 Å (R10170B)
Particles for other applications, such as silica for plugs. Suitable for Organic Molecules (MW < 1,000 Dalton). -
SiliaFlash Irregular Silica Gel GE60, 60 - 200 µm, 60 Å (R10140B)
Particles for Gravity Chromatography: Most economical silica for open column chromatography. Suitable for Organic Molecules (MW < 1,000 Dalton). -
SiliaFlash Irregular Silica Gel WE60, 500 - 1000 μm, 60 Å (R10180B)
Particles for other applications, such as silica for plugs. Suitable for Organic Molecules (MW < 1,000 Dalton). -
SiliaFlash Irregular Silica Gel, 75 - 150 µm, 60 Å (R10137B)
Particles for Gravity Chromatography: Most economical silica for open column chromatography, Suitable for very dirty purification, Easier to handle. Suitable for Organic Molecules (MW < 1,000 Dalton). -
SiliaFlash Irregular Silica Gel, Acid Washed, 40 - 63 µm, 60 Å (R10530B)
Particles for Flash Chromatography: silica for flash & low to medium-pressure preparative chromatography. Narrow particle size distribution, Easier to pack and more uniform packing, Superior resolution, Suitable for use with complex matrices. Suitable for Organic Molecules (MW < 1,000 Dalton). -
-
-
SiliaFlash Irregular Silica Gel FE90, 40 - 63 µm, 90 Å (R10130D)
Particles for Flash Chromatography: silica for flash & low to medium-pressure preparative chromatography. Narrow particle size distribution, Easier to pack and more uniform packing, Superior resolution, Suitable for use with complex matrices. Suitable for Peptides (1,000 < MW < 10,000 Dalton). -
SiliaFlash Irregular Silica Gel, BE90, 200 - 500 µm, 90 Å (R10170D)
Particles for other applications, such as silica for plugs. Suitable for Peptides (1,000 < MW < 10,000 Dalton). -
SiliaFlash Irregular Silica Gel NE90, 500 - 1000 μm, 90 Å (R10180D)
Particles for other applications, such as silica for plugs. Suitable for Peptides (1,000 < MW < 10,000 Dalton). -
SiliaFlash Irregular Silica Gel, 60 - 200 µm, 90 Å (R10140D)
Particles for Gravity Chromatography: Most economical silica for open column chromatography. Suitable for very dirty purification, Easier to handle. Suitable for Peptides (1,000 < MW < 10,000 Dalton). -
-
-
SiliaFlash Irregular Silica Gel M150, 60 - 120 µm, 150 Å (R10150H)
Particles for Gravity Chromatography: Most economical silica for open column chromatography. Suitable for very dirty purification, Easier to handle. Suitable for Peptides (1,000 < MW < 10,000 Dalton). -
SiliaFlash Irregular Silica Gel B150, 250 - 500 µm, 150 Å (R10072H)
Particles for other applications, such as silica for plugs. Suitable for Peptides (1,000 < MW < 10,000 Dalton). -
SiliaFlash Irregular Silica Gel FE150, 40 - 63 µm, 150 Å (R10130H)
Particles for Flash Chromatography: silica for flash & low to medium-pressure preparative chromatography. Narrow particle size distribution, Easier to pack and more uniform packing, Superior resolution, Suitable for use with complex matrices. Suitable for Peptides (1,000 < MW < 10,000 Dalton). -
SiliaFlash Irregular Silica Gel GE150, 75 - 250 µm, 150 Å (R10140H)
Particles for Gravity Chromatography: Most economical silica for open column chromatography. Suitable for very dirty purification, Easier to handle. Suitable for Peptides (1,000 < MW < 10,000 Dalton). -
SiliaFlash Irregular Silica Gel BE150, 200 - 500 µm, 150 Å (R10170H)
Particles for other applications, such as silica for plugs. Suitable for Peptides (1,000 < MW < 10,000 Dalton). -
SiliaFlash Irregular Silica Gel, NE150, 500 - 1000 μm, 150 Å (R10180H)
Particles for other applications, such as silica for plugs. Suitable for Peptides (1,000 < MW < 10,000 Dalton). -
SiliaFlash Irregular Silica Gel, 120 - 200 µm, 150 Å (R10160H)
Particles for Gravity Chromatography: silica for standard open column chromatography. Narrow particle size distribution enables uniform packing, Suitable for mass overload purification. Suitable for Peptides (1,000 < MW < 10,000 Dalton) -
-
SiliaFlash Irregular Silica Gel, FE300, 40 - 63 µm, 300 Å (R10130M)
Particles for Flash Chromatography: silica for flash & low to medium-pressure preparative chromatography. Narrow particle size distribution, Easier to pack and more uniform packing, Superior resolution, Suitable for use with complex matrices. Suitable for Peptides (1,000 < MW < 10,000 Dalton). -
SiliaFlash Irregular Silica Gel GE300, 60 - 200 µm, 300 Å (R10140M)
Particles for Gravity Chromatography: Most economical silica for open column chromatography. Suitable for very dirty purification, Easier to handle. Suitable for Peptides (1,000 < MW < 10,000 Dalton). -
SiliaFlash Irregular Silica Gel, 200 - 500 µm, 300 Å (R10170M)
Particles for other applications, such as silica for plugs. Suitable for Peptides (1,000 < MW < 10,000 Dalton).