Follow SiliCycle on Facebook Follow SiliCycle on Twitter Follow SiliCycle on LinkedIn Watch our videos on Youtube

SiliaSep BT - Biotage™ Compatible

SiliaSep BT cartridges are designed to enhance your purifications when using Biotage™ Flash 75 or 150 development-scale purification systems, or Biotage™ Flash 400 large-scale purification system.

These cartridges offer a faster and safer solution compared to traditional glass columns, and allow purification up to 2.7 kg of sample.

Cartridge Type75S75M75L
Cartridge Code75iS75iM75iL
Silica Weight200 g400 g800 g
Qty/boxBare: 2 / bonded: 1
Dimensions (ID x Length)75 x 90 mm75 x 170 mm75 x 350 mm
Column Volume300 mL500 mL1 L
Recommended Flow Rate100 - 250 mL
Loading Capacity0.2 - 20 g0.4 - 40 g0.8 - 80 g
Max Operating Pressure90 PSI / 6.5 bar (inside the compression module)

We offer a large variety of sorbents to meet any separation need, whether you require reversed-phases, normal phases, ion exchange phases or even metal scavenging phases. You will find below the most popular phases, please contact us if you need an alternative selectivity.

SiliaSep TypePNDescription
SiliaSep SilicaFLH-R10030B-BTMost popular sorbent for day-to-day use for the purification of non-ionic polar organic compounds.
SiliaSep C18 (17% mono)FLH-R33230B-BTIndicated for the purification of low to high polarity compounds.
Provides reproducible purification without the complexity and cost of preparative HPLC.
SiliaSep CyanoFLH-R38030B-BTVersatile sorbent that can be used either as normal or reversed-phase. Indicated for products with immediate to extreme polarity. The slightly hydrophobic nature of the cyano group offers alternative selectivity.
SiliaSep WAX nec (Amine)FLH-R52030B-BTA weak anion exchanger with a pKa of 9.8. At pH 7.8 or below, the functional groups are positively charged. It facilitates the rapid release of very strong anions such as sulfonic acids that may be too strongly retained on SAX.
SiliaSep Diol necFLH-R35030B-BTGood alternative for difficult separation of low to medium polarity samples. Useful for mono and polysaccharides separation. Can be used in HILIC mode.
SiliaSep SCX-2 (Propylsulfonic Acid)FLH-R51230B-BTDue to its very low pKa (< 1) this strong cation exchanger maintains a negative charge throughout the pH scale. The most common use is likely for catch and release purification of weak cations (for example basic drugs and analgesics), analysis of basic biomolecules (peptides and proteins) and water-soluble vitamins (basic vitamins B and C).

6 Item(s)

Set Descending Direction
per page

List  Grid 

  1. SiliaSep BT Flash Cartridges, Silica, 40 - 63 µm, 60 Å (FLH-R10030B-BT)

    SiliaSep BT Flash Cartridges, Silica, 40 - 63 µm, 60 Å (FLH-R10030B-BT)

    Most popular sorbent for day-to-day use for the purification of non-ionic polar organic compounds. SiliaSep BT flash cartridges are compatible with Biotage™ i-style compression modules.
  2. SiliaSep BT Flash Cartridges, C18 (17%) monomeric, 40 - 63 µm, 60 Å (FLH-R33230B-BT)

    SiliaSep BT Flash Cartridges, C18 (17%) monomeric, 40 - 63 µm, 60 Å (FLH-R33230B-BT)

    Indicated for the purification of low to high polarity compounds. Provides reproducible purification without the complexity and cost of preparative HPLC. SiliaSep BT flash cartridges are compatible with Biotage™ i-style compression modules.
  3. SiliaSep BT Flash Cartridges, Cyano (CN), 40 - 63 µm, 60 Å (FLH-R38030B-BT)

    SiliaSep BT Flash Cartridges, Cyano (CN), 40 - 63 µm, 60 Å (FLH-R38030B-BT)

    Versatile sorbent that can be used either as normal or reversed-phase. Indicated for products with immediate to extreme polarity. The slightly hydrophobic nature of the cyano group offers alternative selectivity. SiliaSep BT flash cartridges are compatible with Biotage™ i-style compression modules.
  4. SiliaSep BT Flash Cartridges, Amine, 40 - 63 µm, 60 Å (FLH-R52030B-BT)

    SiliaSep BT Flash Cartridges, Amine, 40 - 63 µm, 60 Å (FLH-R52030B-BT)

    A weak anion exchanger with a pKa of 9.8. At pH 7.8 or below, the functional groups are positively charged. It facilitates the rapid release of very strong anions such as sulfonic acids that may be too strongly retained on SAX. SiliaSep BT flash cartridges are compatible with Biotage™ i-style compression modules.
  5. SiliaSep BT Flash Cartridges, Diol nec, 40 - 63 µm, 60 Å (FLH-R35030B-BT)

    SiliaSep BT Flash Cartridges, Diol nec, 40 - 63 µm, 60 Å (FLH-R35030B-BT)

    Good alternative for difficult separation of low to medium polarity samples. Useful for mono and polysaccharides separation. Can be used in HILIC mode. SiliaSep BT flash cartridges are compatible with Biotage™ i-style compression modules.
  6. SiliaSep BT Flash Cartridges, Propylsulfonic Acid (SCX-2), 40 - 63 µm, 60 Å (FLH-R51230B-BT)

    SiliaSep BT Flash Cartridges, Propylsulfonic Acid (SCX-2), 40 - 63 µm, 60 Å (FLH-R51230B-BT)

    Due to its very low pKa (< 1) this strong cation exchanger maintains a negative charge throughout the pH scale. The most common use is likely for catch and release purification of weak cations (for example basic drugs and analgesics), analysis of basic biomolecules (peptides and proteins) and water-soluble vitamins (basic vitamins B and C). SiliaSep BT flash cartridges are compatible with Biotage™ i-style compression modules.