Halocetic Acids
> back to Suggested SPE Protocols
Matrix
Surface water
Analytes
Chloroacetic Acid, Bromoacetic Acid, Dichloroacetic Acid, Dalapon, Trichloroacetic Acid, Bromochloroacetic Acid, Bromodichloroacetic Acid, Dibromoacetic Acid, Chlorodibromoacetic Acid, Tribromoacetic Acid
SPE Cartridge
SiliaPrep SAX
500 mg / 6 mL
SPE-R66530B-06P
Sample Pretreatment before Loading
Add 0.5 mL of aqueous Ammonium Chloride to 50 mL of water sample. Adjust pH to 4.5 - 5.5 with Sulfuric Acid.
Conditionning
10 mL of Methanol
Equilibration
10 mL of Water
Loading
Pretreated sample
Washing
10 mL of Methanol
Elution
3 mL of 10 % Sulfuric Acid / Methanol
Further Treatment
Esterification and identification by GC/μECD.
-
SiliaPrep SPE Cartridges, TMA Chloride (SAX) nec (SPE-R66530B)